A plug-in home battery needs to know how much electricity you are importing or exporting at any given moment. For that, you need a meter at your connection point. The two common solutions are a P1 meter and a CT meter. In this guide you can read what they measure, how to connect them and which one suits your situation.
In brief
- A P1 meter reads the data that your digital meter already measures itself, via the P1 port.
- A CT meter measures using current clamps around the cables in your fuse box.
- In Flanders, you activate the P1 port via Mijn Fluvius (port management).
- Current clamps are fitted in the fuse box: if in doubt, have an electrician do it.
- Not every meter works with every battery. Check compatibility per model.
Why a meter is needed
Without measurement, a battery can only follow a fixed schedule, for example delivering the same power every evening. You then run the risk that it sends electricity into the grid when you are consuming little, or delivers too little when you are consuming a lot. With a meter at your connection point, the battery can continuously match its power to what your home needs at that moment.
In Belgium, Synergrid requires an energy management system for a plug-and-play battery that measures at the connection point, via the P1 port or via an EnFluRi sensor. Since 15 October 2025, the P1 port has counted as a fully fledged alternative to the EnFluRi sensor (Synergrid, accessed 27/09/2026). More about the Belgian rules on rules in Belgium.
The P1 meter
What does it measure?
The P1 port is a data port on the digital meter. It regularly transmits the current import and export, together with the meter readings. A P1 meter (also called a P1 reader) is a small device that you plug into that port and that passes the data wirelessly to your battery or to an app. So it doesn't measure anything itself: it reads what your digital meter already measures.
Activating the P1 port
In Flanders, the P1 port is not open automatically. You activate it in Mijn Fluvius via port management (Fluvius, accessed 27/09/2026). A P1 reader can then read the data. In other regions and countries the process is different; ask your grid operator.
Advantages and points to note
- You don't need to work in the fuse box.
- The measurement matches what your grid operator records.
- You need a digital meter with an active P1 port.
- The P1 reader needs a stable wireless connection; a meter cupboard in the basement can make this difficult.
- The rate at which the meter transmits data partly determines how quickly the battery can adjust.
The CT meter
What does it measure?
CT stands for current transformer: a current clamp that clips around a cable and measures the current through it, without cutting the cable. A CT meter consists of one or more clamps and a measuring module. With a three-phase connection you usually use one clamp per phase. The module calculates the power and sends it to the battery.
Fitting in the fuse box
The clamps go around the main cables after your meter, in or near the fuse box. These are live, and a mistake can be dangerous or damage your installation. If you are not familiar with electrical installations, leave the fitting to an electrician. Also pay attention to the direction of the clamp: an incorrectly fitted clamp measures export as import.
Advantages and points to note
- Also works if you don't have a digital meter or can't use the P1 port.
- Often measures quickly and directly.
- Requires work in the fuse box.
- Whether a CT meter is sufficient as the measurement for a plug-in battery in your country or region is something you need to check in the rules. Read rules by country.
Comparison at a glance
| Aspect | P1 meter | CT meter |
|---|---|---|
| Measuring point | Digital meter, via the P1 port | Cables in the fuse box |
| Installation | Plug into the port | Fit clamps around cables |
| Requirement | Digital meter with active P1 port | Access to the fuse box |
| Electrician | Usually not needed | Recommended if in doubt |
| Compatibility | Per battery brand and model | Per battery brand and model |
Compatibility: not every meter works with every battery
Battery manufacturers usually support their own meters and a limited number of third-party meters. A meter that works with one brand does not automatically work with another. Even within a brand, support can differ per model or per software version. In addition, there are still models whose operation with Belgian P1 meters has yet to be confirmed. So always check per model which meters are supported. In the comparison we show per model which metering solutions are stated, and in the smart meters collection you will find meters with their compatibility.
Which one should you choose?
- Do you have a digital meter and can you activate the P1 port? Then a P1 meter is usually the simplest route.
- Do you not have a digital meter or a usable P1 port, or do you have an installation where you want to measure at a different point? Then a CT meter can be a solution, fitted by someone who knows what they are doing.
- Either way: choose your battery first, and then a meter that is supported by that model.
Further reading
- How does a plug-in home battery work?
- Safe placement and connection
- A plug-in home battery with a dynamic tariff
- Tool: the product finder takes your meter type into account.